ZC-YJLV22-8.7/15kV-3×150 high-voltage aluminium armoured flame-retardant power cable

Product Overview

ZC-YJLV22-8.7/15kV-3×150 high-voltage aluminium armoured flame-retardant power cable is an engineering-special medium & high voltage power cable with ZC-class flame retardancy, high voltage withstand, armoured protection, weather & corrosion resistance and low power loss. Rated at 8.7/15kV, it adopts standard 3-core large cross-section high-voltage configuration of 3×150mm². Constructed with high-purity aluminium conductor, high-voltage dedicated XLPE cross-linked insulation, steel tape armour mechanical protection and flame-retardant weather-resistant outer sheath multi-layer structure, it integrates multiple merits including stable high-voltage insulation, compression & damage resistance, corrosion & ageing resistance, flame retardancy, low transmission loss, strong heavy-load capacity and wide adaptability to working conditions. It is specially designed for harsh operating conditions such as 15kV medium & high voltage grid transmission, new energy boosting and industrial high-voltage distribution. Suitable for main line laying of large municipal, industrial and new energy high-voltage power projects, it can withstand long-term operation in complex harsh outdoor and underground environments. Featuring safe and stable operation and prominent engineering economy, it is the preferred mainstream dedicated cable for new construction and renovation of medium & high voltage power projects at present.

Main Advantages

  1. High voltage withstand rating, compatible with 15kV medium & high voltage transmission systems Rated at 8.7/15kV, this product is suitable for medium and high voltage power systems including main transmission lines of urban power grids, high-voltage distribution in industrial parks, outgoing cables of PV and wind power booster stations, and high-voltage power supply for mines. It fully meets strict requirements for high-voltage transmission, long-distance power delivery and large-capacity load supply in large-scale projects. Featuring uniform and stable insulation withstand voltage and sufficient insulation margin, it is less prone to insulation breakdown, partial discharge and voltage attenuation under long-term high-voltage operation. It ensures safe, stable and continuous power supply of high-voltage transmission lines and fits various key medium & high-voltage power engineering projects.
  2. Reinforced armoured mechanical protection with outstanding compression and damage resistance The cable adopts high-quality steel tape armour with inner and outer double-layer sheaths. Compared with ordinary high-voltage cables, it delivers excellent resistance against extrusion, impact, crushing and tensile force. It effectively protects against external damage such as heavy soil & stone pressure, mechanical collision during construction, compression caused by foundation settlement and piercing by hard objects in direct underground burial. It prevents power outage, electric leakage and breakdown accidents triggered by mechanical damage to high-voltage lines, greatly improving safety and stability of cables laid underground, in pipe galleries and tunnels.
  3. Corrosion and weathering resistance for harsh outdoor and buried working conditions Constructed with high-performance XLPE cross-linked polyethylene insulation and flame-retardant weather-resistant outer sheath together with sealed armoured protection system, it boasts excellent high & low temperature resistance, anti-ageing, anti-oxidation, moisture & waterproof performance and acid-alkali corrosion resistance. It can withstand harsh complex environments such as outdoor exposure to sunlight and rain, alternating seasonal temperature changes, underground ponding and saline-alkali soil corrosion. It resists cracking, sheath peeling and insulation ageing failure after long-term laying, greatly extending the service life of high-voltage cables and reducing power grid operation, maintenance and cable replacement costs.
  4. ZC-class flame retardant protection with superior fire safety for high-voltage projects The whole cable is manufactured with specially formulated ZC flame-retardant material and meets flame retardancy standards. It features excellent self-extinguishing and fire suppression performance to restrain flame spread. In scenarios of densely laid cables, enclosed high-voltage pipe galleries and concentrated wiring in substations, it effectively stops fire spreading along high-voltage lines. It avoids large-scale power grid paralysis and equipment damage caused by ignition of a single cable section, fully complying with fire safety specifications for municipal high-voltage power grids, industrial high-voltage distribution and new energy booster stations.
  5. Stable electrical performance and low transmission loss under heavy high-voltage loads Made of finely stranded high-purity aluminium conductors, it has good conductivity, uniform resistance and low transmission loss. It generates low temperature rise under full high-voltage load and provides stable and sufficient current-carrying capacity to continuously carry large-capacity high-voltage loads of power grids and industries. The high-voltage dedicated XLPE insulation layer features ultra-high dielectric strength, good sealing and uniform electric field distribution, with outstanding resistance to partial discharge, leakage and high-voltage breakdown. It guarantees 24-hour uninterrupted, highly safe and precise stable operation of medium & high voltage power transmission systems.

Technical Specifications

Item Specification
Conductor Material Finely stranded high-purity aluminium conductor (high-conductivity aluminium core for high voltage)
Insulation, Sheath & Armour Material High-voltage XLPE cross-linked polyethylene insulation, steel tape armour, ZC-class flame-retardant weather-resistant PVC outer sheath
Core Configuration 3×150 (3-core high-voltage power structure, 150mm² per core)
Rated Voltage 8.7/15kV (for medium & high voltage power transmission in industry and power grid)
Flame Retardant Class ZC Class C flame retardant, bundled & single vertical burning flame retardant
Maximum Long-term Operating Temperature 90℃
Minimum Installation Temperature Not lower than 0℃
Environmental Characteristics High voltage withstand, compression & damage resistant, corrosion & moisture resistant, weather-proof & anti-ageing, flame retardant; suitable for outdoor overhead laying, underground direct burial, cable tunnels, pipe galleries and substation installation
Conductor Characteristics High conductivity, low loss, stable power transmission, strong heavy-load capacity; suitable for long-term continuous load transmission in medium & high voltage power grids and new energy power stations

Application

ZC-YJLV22 15kV flame-retardant aluminium armoured cable serves as the main transmission cable for medium & high voltage power grid engineering. With 3-core large cross-section power structure, excellent high-voltage insulation, strong mechanical protection and high flame-retardant safety factor. It applies to renovation of municipal urban high-voltage power grids, urban main high-voltage transmission lines, 15kV high-voltage distribution in industrial parks, high-voltage outgoing cables of PV and wind power booster stations, high-voltage power supply for industrial and mining enterprises, electromechanical high-voltage distribution for highways, concentrated laying in cable tunnels and enclosed pipe galleries, long-distance buried power transmission in wild areas. It can run stably for a long time under harsh environments including outdoor sun exposure, drastic temperature variation, humid corrosion and mechanical extrusion. Widely adopted in new energy power, municipal power, industrial power, traffic power and other key medium & high voltage projects, it is a mainstream cost-effective supporting cable for 15kV high-voltage transmission systems.

Reviews

There are no reviews yet.

Be the first to review “ZC-YJLV22-8.7/15kV-3×150 high-voltage aluminium armoured flame-retardant power cable”

Your email address will not be published. Required fields are marked *